KEVWire

Security intelligence, with context.

Response snapshot Nov 4, 2026, 23:06 UTC

Back to the wire
Permalink
VulnerabilityCVE-2025-54304

An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices.

An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.

At a glance

Exploited
Not known
Severity
9.8 Critical (CVSS 3.1)
Chance of exploitation
Not estimated
Sources
2 independent sources

What to do

Check the vendor advisory for affected versions and fixes.

Read NVD CVE-2025-54304 (opens a new tab)

What happened

An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15.

If a device is powered on and later connected to a network with DHCP, the device may not be assigned the 192.168.2.15 IP address, leaving the display server accessible by other devices on the network. The exposed X11 display server can then be used to gain root privileges and the ability to execute code remotely by interacting with matchbox-desktop and spawning a terminal.

NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

Scores and how they were measured

CVSS base severity

9.8

Version 3.1As of

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Measurement source (opens a new tab)

How bad it is if exploited. Not a prediction of exploitation or proof you are exposed.

EPSS probability

Not available

A model's estimate of exploitation in the next 30 days, not certainty or your own risk.

Related technology

Sources

  1. Primary source

    NVD CVE-2025-54304 (opens a new tab)

    NVD record: description, CVSS (the CNA score is preferred), affected products, and publication date. Not evidence of exploitation.

    Published Checked

  2. Primary source

    Vendor advisory (via NVD references) (opens a new tab)

    The vendor advisory referenced by the CVE record, for affected versions and fixes.

    Published Date not suppliedChecked

  3. Primary source

    NVD CVE API 2.0 (opens a new tab)

    The NVD API page that supplied this CVE record.

    Published Date not suppliedChecked

  4. Primary source

    NVD CVE API 2.0 (opens a new tab)

    The NVD API page that supplied this CVE record.

    Published Date not suppliedChecked

Cite this record

For factual claims, cite the primary sources above; cite KEVWire for its compilation, dates, and classifications.

APA

KEVWire. (2026, November 4). An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. (CVE-2025-54304). https://kevwire.com/record/CVE-2025-54304

MLA

"An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. (CVE-2025-54304)." KEVWire, 4 Nov. 2026, kevwire.com/record/CVE-2025-54304.

Chicago

KEVWire. "An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. (CVE-2025-54304)." Last modified November 4, 2026. https://kevwire.com/record/CVE-2025-54304.

Evidence summary (plain text)

An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. (Dec 4, 2025).
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the device may not be assigned the 192.168.2.15 IP address, leaving the display server accessible by other devices on the network.
CVSS 9.8 (version 3.1; evidence as of Nov 4, 2026; https://nvd.nist.gov/vuln/detail/CVE-2025-54304).
Sources:
NVD CVE-2025-54304: https://nvd.nist.gov/vuln/detail/CVE-2025-54304
Vendor advisory (via NVD references): https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf
NVD CVE API 2.0: https://services.nvd.nist.gov/rest/json/cves/2.0?lastModStartDate=2026-11-04T21:26:17.946Z&lastModEndDate=2026-11-04T23:00:56.752Z&resultsPerPage=500&startIndex=0
NVD CVE API 2.0: https://services.nvd.nist.gov/rest/json/cves/2.0?lastModStartDate=2026-11-04T20:50:59.749Z&lastModEndDate=2026-11-04T22:25:56.739Z&resultsPerPage=500&startIndex=0
Record ID: CVE-2025-54304.
Record origin: Ingested record.
AI evidence: Not assessed.
Known exploitation: Not assessed.
Zero-day status: Not assessed. KEV membership alone does not establish zero-day status.
About this data

This record was ingested from a data source. Retrieved: Nov 4, 2026, 23:00 UTC. Ingestion is not an independent editorial investigation.

NVD status: Analyzed. Publication in the NVD is not evidence of exploitation.

A CISA KEV listing documents known exploitation, not necessarily a zero-day; absence from the catalog does not prove a vulnerability has never been exploited.

Technology tags indicate possible relevance, not verified exposure. Confirm the affected product, version, and configuration against your own inventory; KEVWire does not scan your systems.

A personal reading checklist on this device, not verified remediation.

Record JSON

Your account

Email alerts

Email alerts are coming as part of KEVWire Premium: join the waitlist. To follow your stack today, use its RSS feed, which honors your filters, or connect an AI agent through the API.

Suggest an improvement

Ideas, missing sources, corrections, and bugs are all welcome. No account needed. Suggestions are reviewed by a person before anything changes.

Record details

Record detail